<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Publication:
Imaging the Electrical Resistivity Structure of a Locked Fault Segment: The Ganos Fault example

Loading...
Thumbnail Image

Institution Authors

Advisor

Department

Journal Title

Journal ISSN

Volume Title

Publisher

Copernicus GmbH

Research Projects

Organizational Units

Journal Issue

Abstract

The Ganos Fault, in the westernmost part of the North Anatolian Fault Zone (NAFZ), stayed quiet for approximately 146 years before two catastrophic events shook the area in the summer of 1912. The historical records point out that two devastating activities shook both sides of the Marmara Sea in 1766, too. Following the 1766 events, on August 9th, 1912, two blocks of the dextral Ganos Fault shifted one more time to create an Mw = 7.4 event near M&amp;#252;refte in Tekirda&amp;#287;. Nearly a month later, further to the west, the fault zone moved on September 13th, forcing another disastrous Mw= 6.8 earthquake. Almost 112 years have passed since then (leaving approximately 34 more years to complete the recurrence), and the Ganos Fault is again acting as a seismic gap. In brief, the Ganos Fault tends to generate another series of earthquakes in the region, and the fault zone characteristics of this locked segment are poorly known. In this study, magnetotellurics (MT) method is utilized to image the crustal electrical resistivity structure for deciphering the fault zone geometry. With this object in mind, simultaneous electric and magnetic observations were made at nearly 40 sites in two campaigns. For each observation point, the collected data were transferred to the frequency domain where the electromagnetic impedance tensor elements were calculated with robust processing algorithms (Birrp) for wideband frequencies. Following the dimensionality analyses performed with various tools such as Groom and Bailey decomposition, phase tensor analysis, etc., which eventually pointed out a geo-electric strike angle of nearly ~N60oE, numerical models based on two- and three-dimensional algorithms (such as MT2D and ModEM) were developed to image the fault zone properties of the Ganos Fault. Several numerical models were calculated to realize the influence of the coast-effect caused by the Marmara Sea. Pre-modeling analysis results and the final models suggest that (i) the geo-electric strike angle of ~N60oE agrees well with the earlier results, the geology and the fault&amp;#8217;s geometry, (ii) the Ganos Fault acts as a geological boundary between the Eocene-aged Ke&amp;#351;an Formation in the north and Miocene-aged &amp;#199;engelli Formation in the south, (iii) while the Ke&amp;#351;an Formation defines a continuous tubular highly resistive zone (~500- 800 &amp;#937;m) that may be acting as the seismogenic zone along the Ganos Fault, the &amp;#199;engelli Formation appears to be less resistive in coherent with the ages of the formations highlighted earlier, (iv) the aforementioned resistive block reaches to a depth of nearly 15 - 18 km and this feature may mark the bottom of the seismogenic zone.&amp;#160;&amp;#160;&amp;#160;&amp;#160;&amp;#160;&amp;#160;&amp;#160;&amp;#160;&amp;#160;&amp;#160;

Description

Journal or Series

ISSN

ISBN

Rights

Keywords

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators
Google Scholar
Scholar'da Ara ↗