Publication: Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study
Loading...
Date
Advisor
Department
Journal Title
Journal ISSN
Volume Title
Publisher
AVES YAYINCILIK A.Ş.
Type
Abstract
Abstract Objective: The purpose of this study was to biomechanically compare cable, trochanteric grip plate, and locking plate techniques in Vancouver type AG fracture model in an in vitro test environment. Methods: Fifteen pieces of fourth-generation synthetic femora were separated into 3 groups of 5 models each. A greater trochanteric fracture model was created after femoral stem implantation. Group 1 was fixated with only cable, Group 2 with trochanteric grip plate, and Group 3 with locking plate. Horizontal stiffness, axial stiffness, and failure loads were compared between the groups. Results: In horizontal compression tests, Group 3 had the highest values, but the only statistically significant difference was between the locking plate group and cable group. Axial distraction test results showed that mean stiffness of Group 1 was 94.6±9.44 N/mm, that of Group 2 was 174.8±28.64 N/mm, and that of Group 3 was 185.6±71.64 N/mm. While locking plate versus cable fixation and grip plate fixation versus cable fixation showed statistically significant differences (p<0.05), comparison of locking plate versus grip plate fixation showed no statistically significant difference (p>0.05). In axial failure load test, Group 3 had the highest results. The only significant difference was between the locking plate and cable groups (p<0.05). Conclusion: In Vancouver type AG fractures stable fixation may be achieved with grip plate fixation and locking plates, with the former ensuring more stable osteosynthesis. Keywords: Biomechanical; cable; locking plate; periprosthetic femoral fracture; top Vancouver type AG; trochanteric grip plate. DOI: 10.3944/AOTT.2015.15.0298 This abstract belongs to the un-edited version of the article and is only for informative purposes. Published version may differ from the current version.
Description
Journal or Series
Acta Orthopaedica et Traumatologica Turcica
ISSN
1017-995X
ISBN
Rights
OPEN
Keywords
Arthroplasty, Replacement, Hip, top Vancouver type AG, Bone Screws, periprosthetic femoral fracture, Biomechanical Phenomena, trochanteric grip plate, Fracture Fixation, Internal, Biomechanical, cable, locking plate, periprosthetic femoral fracture, top Vancouver type AG, trochanteric grip plate., Humans, cable, Femur, Hip Prosthesis, Periprosthetic Fractures, Biomechanical, Bone Plates, Femoral Fractures, locking plate