Publication: Examining the structural geology and exploring geothermal energy production potential of an oil/gas field in Thrace Basin, Turkiye
Loading...
Files
Date
Authors
Advisor
Department
Journal Title
Journal ISSN
Volume Title
Publisher
ITU Graduate School
Type
Abstract
The sedimentary deposits of the Thrace Basin begin with Eocene-aged sediments and end with Miocene-aged sediments. The Thrace Basin consists, from bottom to top of the Eocene aged Keşan Group (Ceylan, Soğucak, Hamitabat, Gaziköy, Fıçıtepe and Karaağaç Formations), Mezardere Formation, Oligocene-aged Osmancık and Danişmen Formations and Miocene-aged Ergene Formation. Trace Basin is the biggest natural gas producer from Oligocene aged Osmancık Formation and Econe aged Mezardere Formations for years in Türkiye. So recently some exploration drillings have been performed to examine the deeper production potential of the field from the older formations such as Keşan Group formations. A commercial exploration company has drilled three deep wells (R-1, I-1 and K-1) in the study area of this PhD dissertation to be able to exlore the basin centered gas accumulation of Thrace Basin in Eocene aged Keşan Group. These three well's total depths are approximately 5,000 m and penetrated 1,000 m thickness in the Keşan Group in average. After drilling, the wells were tested for production and produced gas, condensate and hot water at the wellhead. Then the idea came out for geothermal energy production potential of these kind of hot water production wells. So in this PhD study, the geothermal reserve (heat in-place) and energy production potential of these three wells were examined and results were explained. In this PhD study, first, a static geocellular reservoir model was created as a result of the following stages of construction: Fault modeling (pillar gridding), geometrical modeling (a 200 X 200 grid was created in the "x" and "y" directions), dividing the model into thin layers (layering) (the model was layered so that each layer represent 5 m interval), filling the open well log data into the cells cut by the wells in the model (scale up) and reservoir property modeling (porosity, permeability, facies, volumetric specific heat capacity, temperature, pressure, water saturation) (property modeling). Data analysis was performed to distribute the reservoir properties from the calculated and log data to each cell in the model, and variograms were determined, and a numerical cellular static geological reservoir model was created in Petrel software using Gaussian distribution algorithms, which include all formations in the field. The model, covering 1,212 km2 area, 2,500 m thickness, 755 interlayers and 65 fault lines, is a high-resolution (approximately 23 million reservoir cells) geological reservoir model that provides good ideas about how and which reservoir properties are distributed in each formation and which direction to go if new wells are planned to be drilled. It is a helpful field development model in determining the location of new wells in the field and in providing preliminary information about the geological section and reservoir properties expected in the well. Our field studies on the Keşan Group has shown that the main bedding direction of the Keşan Group is ENE-WSW. It is also observed that some beddings are oriented NE-SW. The dip of the beddings are generally horizontal. The joints have generally high angle dips (>60) and major strike direction is NNW-SSE. Furthermore, less pronounced ones are NW-SE, E-W and NE-SW directed. In the study field, it was observed that some of the joint sets are related to the folding representing orthogonal and shear joints. Others are extensional joints. Joints are generally not filled but some calcite fillings were also observed. Because rocks are mostly fine-grained (fine sandstone, siltstone, or shale) fracture density is high (closely spaced). Joints are penetrative structures, which allow natural permeability in the rocks, especially in low porous rock types. The orthogonal and radial joints are parallel and perpendicular to the fold axis. The main fault direction of the Keşan Group is NW-SE. Some faults are oriented E-W. Especially syn-sedimentary faults measured in the region indicating the opening direction of the basin, which is NE-SW. However, because almost all rock types are clastic they do not have much slickenlines on the slickensides. Synthetic and antithetic normal faults, reverse faults, oblique and strike-slip faults were observed in the study area. The normal faults having dip values higher than 65º, are NE dipping and related to basin opening but reverse faults are both NW and SE dipping probably formed during the closure of the basin having high dip values reminding reworked faults (reworked earlier normal faults). Oblique faults have NNW-SSE and roughly E-W striking faults. E-W striking faults may be related to the North Anatolian Fault Zone (NAFZ) but others may represent transfer faults. The absence of fracture systems in the NE-SW direction indicates that good reservoir permeability should not be expected in this direction. The fault orientations obtained from the surface data are in the same direction with the fault interpretations made in the Petrel software. Although the paleocurrent data are quite scattered in the NW-SE direction, they represent the fan delta system and show that the paleocurrent direction is NW-SE. In calculating the amount of heat and producible power for geothermal reservoirs, the volumetric stored heat (or "heat in place") method proposed by the US Geological Survey (USGS) in the 1970s was frequently used. The USGS volumetric method is quite attractive due to its simplicity in evaluating the stored heat or volumetric aspects of geothermal resources. In 2006, the MIT method was proposed for binary geothermal power conversion systems. However, with the significant development of geothermal resources in recent years, experience gained over the past decades has shown that the use of these methods, as first proposed, overly optimistically estimates the real power potential. Much of the problem stems from the production (or recovery) factor used in the calculations, the resource volume that can be produced, and the ambient temperature (or leaving temperature) values that are often arbitrarily low for the reference temperature. For example, while many studies use a reference temperature of 15 C in the USGS method, some studies use 25 C, some use 35 C, and some use 100 C. These arbitrary reference temperature values can be used for stored heat calculations, but they are not realistic for estimating the heat and electricity production that can be produced at the wellhead. Recent studies have shown that the reference temperature should be selected by considering specific power conversion systems, such as single-flash and binary, to obtain realistic estimates of the heat that can be produced. This approach provides an appropriate calculation of the available work and conversion efficiency for the power plant that can be used in power conversion. This method is based on the actual operating conditions of the power conversion system, considering the second law of thermodynamics in the calculation of the amount of heat in place and power potential that can be produced. In this method, we cannot take values such as reference temperature, turbo generator power conversion efficiency as a fixed value that we estimate. These values are determined according to the actual operating conditions of the power conversion system and thus the reserve approach we will make will be much more realistic compared to the USGS and/or MIT methods. In addition, it is suggested to use the value of 75% for conversion efficiency in the use of this method. The on-site heat and producible power potential calculations made in this doctoral study have yielded more realistic results since they were made with appropriate calculations considering the thermodynamics of the constructed power conversion system. The R-1, K-1, and I-1 wells drilled in the Thrace Basin were completed by drilling 855 m, 874 m, and 1,241 m thickness in the Keşan Group, respectively. The static reservoir temperature values obtained from these three wells targeting the Eocene-aged Keşan Group are an average of 165 oC. Hot water and gas production from these wells were tested together in the wellhead tests. Wellhead water temperature values were measured between 75-90 oC. No study has been conducted to date investigating the geothermal reserve and producible geothermal power potential of the Keşan Group. The geocellular model of the Keşan Group was made by determining a boundary polygon formed by three deep wells drilled in the region. The model covers an area of 482 km2, 1,000 m thickness and consists of 65,000 cells. The parts of the 3D seismic interpretations outside this area were cropped, and the mud log data obtained from the drilled wells, formation entry depths and other open hole log data were evaluated together with the effective porosity, water saturation, volumetric specific heat capacity, geothermal stored heat in-place, reserve and producible power potential were calculated with two different methods with probabilistic data. In the first method, the values for each cell in the created geocellular statistical model were calculated separately, and P10 (proved), P50 (probable), and P90 (possible) values were calculated. In the second method, mathematical commands and formulas were written, minimum, moderate, and maximum values were given, symmetric triangular value distributions were made within the framework of these values and mathematical probabilistic (P10, P50, P90) results were obtained considering the uncertainty propagation with the Analytical Uncertainty Method. In both methods, calculations were made assuming that a dual fluid geothermal energy power conversion system was constructed in the field and that this power conversion system would be operated for 25 years with a load factor of 0.90 with a turbo-generator cycle efficiency of 75%. The results obtained from both methods showed a difference of 4% and presented very close results. The average geothermal energy production potential from both methods was calculated as 3,265 MWe. The results of the study showed that the Keşan Group is a good candidate in terms of geothermal power production potential and that the Analytical Uncertainty Propagation method provides very close results to geocellular models when there is not enough data to perform geocellular models that require a lot of data for field development and therefore it is a good alternative reservoir estimation method that can be used for field development.
Description
Thesis (Ph.D.) -- Istanbul Technical University, Graduate School, 2025
Journal or Series
ISSN
ISBN
Rights
Keywords
jeoloji mühendisliği, geological engineering, petrol ve doğal gaz mühendisliği, petroleum and natural gas engineering
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Google Scholar
Scholar'da Ara ↗ Bu yayında DOI yok — Altmetric/Dimensions/PlumX/BIP! rozetleri DOI gerektirir.