<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Publication:
Damage and capacity diagnostics of cfrp-jacketed non-ductile rc frames

Loading...
Thumbnail Image

Institution Authors

Item type:Person,
Oyguç, Reşat Atalay
Doçent
Item type:Person,
Yeşilyurt, Ali
Doktor Öğretim Üyesi

Advisor

Journal Title

Journal ISSN

Volume Title

Publisher

Mdpi ag

Research Projects

Organizational Units

Journal Issue

Abstract

Non-ductile reinforced concrete frames with unconfined joints dominate the collapse hazard of the existing building stock. Their CFRP-retrofit margin at collapse demand is poorly quantified. Two one-third-scale portal sub-frames were tested under Froude similitude. Specimen 1 was bare. Specimen 2 carried a three-ply hoop CFRP jacket on columns, beams, and joints. Both received the Antakya 3141 record from the 2023 Kahramanmaraş Mw 7.7 mainshock at design intensity 0.35 g and collapse intensity 1.0 g. Cyclic response was decomposed into flexural, shear, and slip energy. At design intensity, the retrofit cut peak roof drift by 54%, suppressed residual offset, and lowered the calibrated Park–Ang index from 0.89 to 0.32. Slip share dropped from 47% to 5%. At collapse intensity, the retrofitted frame transitioned to joint-panel debonding-controlled failure at 8% drift with 245 mm residual, and shear share rose to 64%. The dominant-half-cycle ratio R1 ≈ 0.72 emerged as a candidate brittle-damage signature for collapse-level response. A Lam–Teng confinement check confirms that the failure migrates from the column ends to debonding fracture in the wrapped panel rather than being eliminated by the retrofit. Supplementary joint-corner anchorage is recommended for non-ductile joints at collapse demand.

Description

Journal or Series

Buildings

ISSN

ISBN

Rights

openAccess

Keywords

Code-versus-observed assessment, Cfrp jacketing, Non-ductile rc frames, Park–ang damage index, Shake-table testing, Hysteretic decomposition, Seismic retrofit

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators