Publication: FFT-based viscosity sensing for a micropillar-based microfluidic chip
Loading...
Files
Date
Authors
Advisor
Journal Title
Journal ISSN
Volume Title
Publisher
Graduate School
Type
Abstract
The measurement of viscosity, a fundamental characteristic of substances, is crucial in specific medical contexts. In order to achieve this objective, scientists have put forward a range of microfluidic viscometers that are capable of accurately determining viscosity with minimal sample size. The research consists of four main parts. In the first chapter, a literature research was conducted and the methods and experiments used in previous research were examined. In the second part of the study, the fabrication methods of the newly designed chip were discussed and the experimental plane used was mentioned in detail. In the third part of the study, the calculation methods, image processing methods and signal processing methods used were mentioned. In this section, the newly proposed two-dimensional FFT method and its advantages over area finding and circular Hough transform method are discussed. In the last part of the study, the advantages of the newly proposed algorithm and some suggestions on what path should be followed in new studies were found. In the last section, the previously used circular Hough transform method was combined with the k-mean algorithm, a classification method, and the pros and cons of this method were mentioned. In addition, a study was conducted to optimize the size and length of chips designed using the newly proposed two-dimensional FFT algorithm before moving on to the design phase. The objective of this study is to examine a microfluidic viscometer that utilizes micropillars. The viscometer measures the flexing of arrays of micropillars composed of flexible polydimethylsiloxane (PDMS) in reaction to the movement of fluid. The microfluidic chips are manufactured using a widely used soft lithography technique. In order to enhance the light absorption of the micropillars in the optical experimental setup, black pigments are included into the PDMS prior to the baking process. The proportions of the black pigment, curing agent, and PDMS have been adopted from a previous study. To determine the deflection of the pillars Two cameras, one positioned above and the other from a side angle, simultaneously record data during a synchronized time period. The experimental configuration consists of two cameras and a laser. The cameras process the recorded frames to quantify the bending angles of the micropillars made from PDMS. The circle detection technique has been employed to ascertain the precise position of the pillar based on the top-down perspective. The Fast Fourier Transform (FFT) is employed to analyze the frame data captured by the side camera and ascertain the bending angles of the micropillars. The acquired image data from two cameras has been processed by interpolation in order to enhance the pixel count of the images for the purpose of evaluating the calculation time and accuracy of two different approaches. The computation time of two approaches has been measured for various conditions, and the introduced method has greatly decreased the calculation time for identical frames. The findings produced from the two calculating approaches exhibit a significant resemblance, with an average inaccuracy of %0.74.
Description
Thesis (M.Sc.) -- Istanbul Technical University, Graduate School, 2024
Journal or Series
ISSN
ISBN
Rights
Keywords
microfluidic chip, mikroakışkan çip, viscosity, viskozite
Citation
Endorsement
Review
Supplemented By
Referenced By
Google Scholar
Scholar'da Ara ↗ Bu yayında DOI yok — Altmetric/Dimensions/PlumX/BIP! rozetleri DOI gerektirir.