<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Publication:
Effect of PVA Addition on SO2Adsorption Properties of GO Fibers

dc.contributor.authorYuksek, Ilkay Ozsev
dc.contributor.authorAlptoga, Ozge
dc.contributor.authorAltay, Pelin
dc.contributor.authorKaratepe, Nilgun
dc.contributor.authorOnen, Aysen
dc.contributor.authorUcar, Nuray
dc.contributor.departmentTekstil Mühendisliği Bölümü
dc.contributor.departmentTekstil Mühendisliği Bölümü
dc.contributor.departmentEnerji Enstitüsü
dc.contributor.departmentKimya Bölümü
dc.contributor.ituauthorYüksek, İlkay Özsev
dc.contributor.ituauthorAltay, Pelin
dc.contributor.ituauthorYavuz, Nilgün
dc.contributor.ituauthorÖnen, Hacer Ayşen
dc.date.accessioned2026-01-26T02:45:07Z
dc.date.issued2018-12-24
dc.description.abstractSince late 20th century, the drawbacks of pollution became obvious which increases the demand for environmental friendly and ecological approaches in all disciplines. Not only using environment friendly materials and procedures, but also detecting any pollution, and potential solutions are also common area of current research. SO2, one of the significant topics in waste management, is reported to cause acidic rain. To abolish SO2 waste, excess temperature is required. The current efforts are to develop materials that can remove SO2 at comparatively low temperatures. The aim of this study is to examine a potential use of graphene oxide (GO) fibers and composite polyvinyl alcohol (PVA) incorporated GO fibers in SO2 filters. So as to observe the effect of PVA incorporation on composite fiber properties, PVA incorporated GO fibers and neat GO fibers were prepared. GO fibers were prepared with modified Hummers method followed by wet spinning through three coagulation baths. For composite fiber formation, 10% PVA was added to coagulation bath three. So formed fiber morphologies were analyzed with SEM, AFM and BET. Electrical conductivities were calculated from electrical resistances measured with conductivity tester. The SO2 adsorption and desorption properties were measured in a quartz reactor. PVA addition did not have a significant effect on electrical conductivity whereas increases the SO2 adsorption capacity and reduces the surface roughness, pore size, pore volume and surface area.
dc.description.urihttps://doi.org/10.1088/1757-899x/460/1/012050
dc.description.urihttps://dx.doi.org/10.1088/1757-899x/460/1/012050
dc.description.urihttps://aperta.ulakbim.gov.tr/record/31217
dc.identifier.doi10.1088/1757-899x/460/1/012050
dc.identifier.eissn1757-899X
dc.identifier.openairedoi_dedup___::c9fcc2526a1201171a91d08a8c2074b0
dc.identifier.orcid0000-0001-7888-9477
dc.identifier.orcid0000-0002-4989-3271
dc.identifier.startpage012050
dc.identifier.urihttps://hdl.handle.net/11527/57983
dc.identifier.volume460
dc.publisherIOP Publishing
dc.relation.ispartofIOP Conference Series: Materials Science and Engineering
dc.rightsOPEN
dc.sdg.typeGoal 13: Climate Action
dc.sdg.typeGoal 11: Sustainable Cities and Communities
dc.sdg.typeGoal 7: Affordable and Clean Energy
dc.sdg.typeGoal 6: Clean Water and Sanitation
dc.sdg.typeGoal 12: Responsible Consumption and Production
dc.titleEffect of PVA Addition on SO2Adsorption Properties of GO Fibers
dc.typeArticle
dspace.entity.typePublication
person.identifier.orcid0000-0001-7888-9477
person.identifier.orcid0000-0002-7392-4103
person.identifier.orcid0000-0002-7169-608X

Files

Collections