In this thesis, the fire safety performance of applicable emergency ventilation strategies in train fires that may occur in different types of metro stations is analyzed in detail. The aim is to identify the most suitable emergency ventilation systems and evaluate their comparative performance under variables such as station type, fire location, fan failure situation, and fire scenario. Managing smoke movement is critical for both evacuation safety and firefighter intervention. The enclosed structure, high density, and limited evacuation routes of metro systems can cause smoke to spread rapidly and pose a threat to safe evacuation. In this context, emergency ventilation design, appropriate fire resistance performance of structures, testing of an effective ventilation system, and periodic maintenance are key elements of fire safety. The study presents a comprehensive approach covering not only emergency ventilation strategy performance but also structural element selection, scenario-based analysis, system testing and maintenance. In the first stage, one-dimensional thermo-flow analyses were performed on the idealised (hypothetical) metro line with Subway Environment Simulation (SES) software. For the study, a metro line consisting of seven stations was designed, and tunnel fire scenarios were studied. The scenarios where the fire occurred in the inclined tunnel created the most challenging conditions; fan failures significantly reduced the system performance, especially when the supply fan in unidirectional tunnels and the exhaust fan in bidirectional tunnels failed. Open cross-passages reduced the smoke velocity. Critical air velocities were calculated, scenarios below these velocities were eliminated and fan capacities were determined for all stations. The tunnel boundary conditions were provided for CFD analyses with the train fire scenario inside the station. In the second stage, three station types (island, side platform, tunnel) were modeled in three dimensions and imported to Fire Dynamics Simulator (FDS) software. Eight scenarios were studied for each of them with different fire locations and fan failure conditions. In addition to the ceiling temperature, tenability criteria such as air velocity, visibility, and Fractional Effective Dose (FED) at 2 meters above the walkway on the evacuation routes were evaluated. Comparing the fire scenarios, the scenario with a 120s delay to the fire curve resulted in higher temperature and earlier loss of visibility. The assumption that there was a non-fire train on the second trackway reduced the air flow and negatively affected the evacuation. Recommended strategies according to station types are summarized as follows: Island type: Symmetrical pull-pull strategy provided balanced smoke exhaust and the system maintained their stability even in case of fan failure. Side platform: The push-pull strategy provided a safer evacuation environment by keeping the smoke in one direction. The pull-pull strategy was found to be more risky due to smoke propagation on all alternative evacuation routes. Tunnel type: The push-pull strategy kept evacuation routes safe, while the pull-pull strategy created backlayering and severely reduced visibility. In addition, passenger evacuation analyses were performed with Pathfinder software using CFD data, and passenger distributions and walking speeds depending on visibility were defined. Especially at the island type station, scenarios based on evacuation simulations only and CFD+Evac combined scenarios were compared. It was found that reduced passenger movement speed in low visibility areas directly affects the evacuation time. This demonstrated the need to integrate environmental conditions during fire incidents into evacuation models. Technical outcomes: In SES analysis, exhausting smoke in the opposite direction of buoyancy effect in inclined tunnel fires are the most challenging scenarios. In SES analysis, fan failures have significant impact on system performance. In SES analysis, open cross-passages reduced smoke velocity. In SES analysis, non-incident trains adversely affect smoke velocity and should be taken into account depending on their likelihood of presence. In SES analysis, worst-case scenarios must be defined by considering factors such as cross-passage and emergency exit/shaft openings, fire location within the tunnel, evacuation direction, non-incident train presence, fan failure condition and tunnel slope. In CFD analysis, generally under-train fires produced faster smoke spread and shorter visibility than fires occurring on top of the train. In CFD analysis, the fire scenario affects tenability criteria. A 120-second delay was applied to the fire curve to account for detection and response time. In CFD, the presence of the second train on the non-fire trackway reduced air velocity and increased temperature of the platform. In CFD analysis, fan failure does not always have a negative impact on evacuation. In scenarios where high turbulence and instabilities adversely affected tenability criteria, the fan failure actually improved overall conditions. In Pathfinder, the designed decrease in walking speeds when visibility decreased caused an increase in evacuation time. The CFD+Evac integration for the island type station produced more realistic results than conventional evacuation-only scenarios. Station specific strategy recommendations: Symmetrical pull-pull for island type, push-pull for side platform and tunnel type were found to be more effective. This thesis presents an engineering-based, scenario-based and numerical modeling-based comprehensive analysis of emergency ventilation strategies that can be applied in metro stations and provides technical contributions for both new system design and improvement of existing infrastructures.

Description

Thesis (M.Sc.) -- Istanbul Technical University, Graduate School, 2025

Journal or Series

ISSN

ISBN

Rights

Keywords

acil durum yönetimi, emergency management, afetler, disasters, yangın söndürme, fire extinction, yangından korunma, fire prevention

Citation

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Bu yayında DOI yok — Altmetric/Dimensions/PlumX/BIP! rozetleri DOI gerektirir.